Naslov Rezonantno uzemljenje neutralne točke srednjenaponskih mreža za distribuciju električne energije
Naslov (engleski) Resonant grounding in medium voltage distribution power systems
Autor Ivan Goran Kuliš
Mentor Ante Marušić (mentor)
Član povjerenstva Sejid Tešnjak (predsjednik povjerenstva)
Član povjerenstva Ante Marušić (član povjerenstva)
Član povjerenstva Matislav Majstrović (član povjerenstva)
Ustanova koja je dodijelila akademski / stručni stupanj Sveučilište u Zagrebu Fakultet elektrotehnike i računarstva (Zavod za visoki napon i energetiku) Zagreb
Datum i država obrane 2003, Hrvatska
Znanstveno / umjetničko područje, polje i grana TEHNIČKE ZNANOSTI Elektrotehnika Elektroenergetika
Univerzalna decimalna klasifikacija (UDC ) 621.3 - Elektrotehnika
Sažetak Na osnovi pojednostavljenog prikaza rada distribucijskih srednjenaponskih mreža pri zemljospoju, ukratko su opisane osnovne značajke načina uzemljenja neutralne točke koji se koriste u svijetu. Opisane su osnovne značajke vezane za sigurnost i kvalitetu napajanja korisnika. Većinu kvarova u distribucijskim srednjenapnskim (SN) mrežama predstavljaju zemljospojevi. Njihov udio u ukupnom broju kvarova tipično prelazi 50 %. S obzirom da uzemljenje neutralne točke značajno utječe na prilike pri zemljospoju, pristup izboru načina uzemljenja neutralne točke zahtijeva ozbiljno razmatranje. Prikazani su problemi koji se javljaju pri zemljospojevima i način na koji se oni rješavaju ugradnjom kompenzacijske prigušnice. Rezonantno uzemljenje je razvojem tehnologija i povećanjem zahtjeva na kvalitetu napajanja postalo prihvatljivim rješenjem i u zemljama u kojima se do nedavno nije koristilo. Prikazana su pozitivna iskustva u radu rezonantno uzemljenih mreža u Francuskoj i Italiji. Francuska i talijanska iskustva su jako zanimljiva s hrvatske pozicije, jer ni oni nisu ranije imali rezonantno uzemljene distribucijske SN mreže. U Francuskoj su SN mreže dominantno uzemljene preko maloomskog otpornika, dok su u Italiji mreže uglavnom neuzemljene. Teorijom parametara i faznim modelom matematički su prikazana načela kompenzacije struje zemljospoja. Na osnovi ovih teorija, u programskom paketu MATLAB isprogramirana je “tipična” 20 kV distribucijska SN mreža na kojoj su prikazane naponske i strujne prilike u zdravoj mreži i pri zemljospoju. Vrste kompenzacijskih zavojnica mogu se podijeliti prema načinu podešavanja te prema tome imaju li željeznu ili zračnu jezgru. Izbor i način priključenja kompenzacijske zavojnice ovisi o tipu VN/SN transformatora, prvenstveno o njegovoj snazi i grupi spoja. S obzirom da se danas najviše ugrađuju, detaljnije su opisane kompenzacijske zavojnice s neprekidnim podešenjem i željeznom jezgrom i kompenzacijske zavojnice s kombinacijom više zavojnica sa zračnom jezgrom. Kako bi se ostvarile sve prednosti rezonantnog uzemljenja, kompenzacijske zavojnice trebaju biti podešene tako da s dozemnim kapacitetima mreže tvore rezonantni strujni krug. Točnost podešenja treba se učestalo provjeravati kako bi se pratile česte promjene konfiguracije mreže. Sustav za podešavanje treba osiguravati da induktivitet kompenzacijske zavojnice uvijek bude blizu “podešenja” odnosno rezonancije. Prikazani su različiti sustavi za podešavanje induktiviteta kompenzacijskih zavojnica, problemi koji se javljaju pri podešavanju te način na koji se ti problemi rješavaju primjenom sustava podešavanja s injektiranjem struje.Zaštita u rezonantno uzemljenim mrežama složenija je nego u neuzemljenim mrežama ili mrežama uzemljenim preko maloomskog otpornika. U rezonantno uzemljenim mrežama klasična vatmetarska zaštita znatno je ograničenija, jer ne može otkrivati zemljospojeve s otporima na mjestu kvara većim od 4 kΩ. Zbog toga se u rezonantno uzemljenim mrežama pored vatmetarske zaštite ugrađuje i dodatna zaštita koja je sposobna selektivno otkrivati i visokoomske zemljospojeve. Osim vatmetarske zaštite prikazane su različite metode zemljospojne zaštite, njihove prednosti i mane te utjecaj na poboljšanje selektivnog otkrivanja zemljospojeva.
Sažetak (engleski) Based on the simplified analysis of a medium voltage network operation during an earth fault, the main types of the neutral grounding (earthing) used in the world are briefly described. Only the essential characteristics of customers supply safety and quality are related. Majority of faults in distribution medium voltage (MV) networks are earth faults. Their share in the total number of faults is typically over 50 %. Considering that neutral grounding makes significant impact to earth fault characteristics, selection procedure the neutral grounding demands serious consideration. Problems that appear during earth faults as well as the way of their solving with resonant grounding system are discussed. Technology development and permanent increase of the power quality demands have made resonant grounding as an acceptable solution, even in the countries which have never used it before. Positive experiences with resonant grounding in France and Italy are presented. The French and Italian experiences are very interesting from a Croatian standpoint. A few years ago in these countries (as in Croatia) the resonant grounding of the MV networks was not used. French networks are dominantly grounded through low ohmic resistors, while Italian networks are mainly operated with isolated neutral. Principles of the earth fault current compensation are described through the parameter theory and the phase model. Based on these theories, the “typical” 20 kV distribution MV network is programmed in the software package MATLAB. This network is used in order to present voltage and current characteristics of the sound network as well as during earth faults. Compensation coils can be divided according to the way of tuning and according to whether or not they have a ferromagnetic core. The selection and the way of connection of the compensation coil depend on the HV/MV transformer type, basically on its rated power and connection. Considering that the compensation coils with continuous tuning and ferromagnetic core as well as the compensation coils made of combination of a few air coils are the most often implemented today, they are described in more details. To use all advantages of the resonant grounding, compensation coils should be tuned to form a resonant circle with the network line to earth (zero sequence) capacitances. Tuning accuracy should be checked frequently for tracking frequent network configuration changes. Tuning system should ensure that the compensation coil inductivity is always close to the resonant point. Different tuning systems, problems that occur in tuning and the way of solving these problems by using a current injection tuning system are presented.Protection in resonant grounded networks is more complicated than the one in low ohmic grounded or isolated networks. In resonant grounded networks the classic watt metric protection is less effective, due to unselective detection of earth faults with fault resistances larger than 4 kΩ. Therefore, in resonant grounded networks, besides watt metric protection, additional protection able to selectively detect high ohmic earth faults should be mounted. Different earth fault protection methods, their advantages and disadvantages as well as the influence on the improvement of the selective earth fault detection are presented.
Ključne riječi
zemljospoj
kompenzacijska zavojnica
rezonantno uzemljenje
kvaliteta napajanja
zemljospojna zaštita
Ključne riječi (engleski)
earth fault
compensation coil
resonant grounding
power quality
earth fault protection
Jezik hrvatski
URN:NBN urn:nbn:hr:168:479518
Studijski program Naziv: Elektrotehnika Vrsta studija: sveučilišni Stupanj studija: poslijediplomski znanstveni (magistarski) Akademski / stručni naziv: Magistar znanosti elektrotehnike (mag. ing. el.)
URL zapisa u katalogu https://lib.fer.hr:8443/cgi-bin/koha/catalogue/detail.pl?biblionumber=29141
Vrsta resursa Tekst
Opseg VI, 101 str. ; 30 cm
Način izrade datoteke Izvorno digitalna
Prava pristupa Zatvoreni pristup
Uvjeti korištenja
Datum i vrijeme pohrane 2019-09-09 09:07:07