Naslov Ispitivanje elektroinstalacija niskog napona
Naslov (engleski) Testing of low voltage electrical installations
Autor Danijel Lončar
Mentor Rene Prenc (mentor)
Član povjerenstva Rene Prenc (predsjednik povjerenstva)
Član povjerenstva Dubravko Franković (član povjerenstva)
Član povjerenstva Saša Vlahinić (član povjerenstva)
Ustanova koja je dodijelila akademski / stručni stupanj Sveučilište u Rijeci Tehnički fakultet (Zavod za elektroenergetiku) (Katedra za električna postrojenja i elektroenergetske sustave) Rijeka
Datum i država obrane 2023-09-21, Hrvatska
Znanstveno / umjetničko područje, polje i grana TEHNIČKE ZNANOSTI Elektrotehnika Elektroenergetika
Sažetak Ispitivanje električnih instalacija niskog napona provodi se kako bi se utvrdila sigurnost i otpornost električne instalacije prema vanjskim utjecajima koji djeluju na instalaciju iz okoline koja istu okružuje za vrijeme čitavog životnog vijeka eksploatacije i sigurnosti korisnika koji upotrebljavaju električnu energiju koja se distribuira kroz električne instalacije niskog napona. Potrebno je utvrditi sigurnost električne instalacije na mehaničku otpornost, otpornost i zaštitu od termičkog djelovanja uslijed preopterećenja i kratkih spojeva, stanje izolacije, osnovnu zaštitu od dodira dijelova pod naponom u normalnom pogonu, dostupnost ugrađene opreme za pregled i održavanje. S aspekta sigurnosti korisnika potrebno je odrediti vrstu zaštite od indirektnog dodira dijelova pod naponom u slučaju kvara. Za određivanje adekvatne zaštite korisnika električne instalacije od indirektnog napona dodira dijelova pod naponom u slučaju kvara potrebno je znati kakav utjecaj ima djelovanje električne struje na tijelo čovjeka u trenutku prolaska struje kroz njegovo tijelo. Tijelo čovjeka predstavlja impedanciju koja se smanjuje povećanjem dodirnog napona. Impedanciju ljudskog tijela moguće je smanjiti povećanjem prijelazne impedancije između dijelova pod naponom koje čovjek može dodirnuti u slučaju kvara. To se postiže adekvatnim izborom električnih trošila koja za napajanje koriste sigurnosni mali napon u SELV, PELV i FELV klasi zaštite i izborom trošila u kućištima s duplom ili pojačanom izolacijom. Drugi tip zaštite je automatski isklop napajanja u slučaju kvara, prije pojave visokog napona dodira koji je opasan za tijelo čovjeka. To se postiže pravilnom izvedbom električne instalacije u TN, TT i IT sustavu uzemljenja u kombinaciji s pravilnim izborom i ugradnjom opreme za automatski isklop napajanja. Električne instalacije u kojima se ne smije isključiti napajanje prilikom pojave kvara se izvode u IT sustavu uzemljenja s kontrolnicima izolacije. Cilj ovakve izvedbe je smanjiti impedanciju petlje kvara na najmanju moguću mjeru, kako bi struja koja može proteći kroz tijelo čovjeka u slučaju kvara bila jakosti koja nije opasna za tijelo čovjeka. TN i TT sustavi uzemljenja s automatskim isklapanjem napajanja djeluju primjenom obrnute logike od IT sustava uzemljenja. Cilj je smanjiti impedanciju petlje kvara kako bi uređaji za automatski isklop napajanja selektivno isključili strujne krugove s kvarom u što kraćem vremenu, prije nego što napon dodira poraste do vrijednosti koja može izazvati protok struje kroz tijelo čovjeka jakosti opasne za ljudsko tijelo.
Sažetak (engleski) Testing of low-voltage electrical installations is carried out in order to determine the safety and resistance of the electrical installation according to the external influences acting on the installation from the environment that surrounds it during the entire lifetime of exploitation and safety of users who use electricity that is distributed through low-voltage electrical installations. It is mandatory to assess the safety of the electrical installation in terms of mechanical durability, resistivity and protection against thermal effects due to overload and short circuits, insulation integrity, basic protection against contact of live components in normal operation, and availability for inspection and maintenance. From the aspect of user safety, it is necessary to determine the form of protection against inadvertent contact with live components in the event of a malfunction. To establish suitable protection for the users of the electrical installation against unintended voltage exposure of touching live parts in the event of a malfunction, it is necessary to understand effects of the electric current on the human body in the moment as the current passes through it. The human body represents an impedance that decreases as the touch voltage increases. It is possible to reduce the impedance of the human body by increasing the transient impedance between live parts that can be touched by a human in the event of a fault. This is achieved by an adequate selection of electrical appliances that use safe low voltage for power supply in the SELV, PELV, and FELV protection class and by choosing appliances enclosed with double or reinforced insulation. Another type of protection is the automatic power cut off in the event of a fault before the appearance of a high contact voltage that is dangerous for the human body. This is achieved by the correct execution of the electrical installation in the TN, TT, and IT grounding systems in combination with the correct selection and installation of equipment for automatic power cut-off. Electrical installations in which the power supply must not be switched off in the event of a fault are carried out in the IT grounding system with insulation’s control elements. The objective of such implementation is to minimize the fault loop impedance to the lowest possible value, so the current that could potentially pass through a human body in case of a fault, to be of an intensity that poses no danger to the human body. TN and TT earthing systems in conjunction with automatic cut off mechanisms operate using the reverse logic of IT earthing systems. The goal is to reduce the impedance of the fault loop so that the automatic power disconnect devices will selectively shut down the faulted circuits in time before the contact voltage rises to a value that can cause current to flow through the human body of a magnitude dangerous to the human body.
Ključne riječi
Djelovanje struje na ljudsko tijelo
direktni napon dodira
indirektni napon dodira
automatski isklop napajanja
impedancija petlje kvara.
Ključne riječi (engleski)
Effect of electric current on the human body
direct touch voltage
indirect touch voltage
automatic power supply cut off
fault loop impedance