Sažetak | Cilj istraživanja: Uporabom računalne dinamike fluida (CFD), analizirati utjecaj vrste i dubine aplikacije irigacijske igle, te ulaznog masenog protoka irigatora, na brzinu, tlak i uzorak protoka irigatora tijekom simulirane endodontske irigacije. Materijal i metode: Nakon instrumentacije, korijenski kanal humanog gornjeg očnjaka ispunjen je kontrastnim fluidom i skeniran pomoću kompjutorizirane tomografije (CT). Trodimenzionalni oblik kanala dobiven obradom CT snimki prenesen je u Computer-Assisted Design (CAD) računalni program. Dvije kontrolne točke, u cilju mjerenja brzine i tlaka irigatora, postavljene su u apeksnom dijelu korijenskog kanala. Tri CAD modela različitih 27G irigacijskih igala (narezana i zakošena igla otvorenog vrha, te igla zatvorenog vrha s otvorom sa strane) postavljene su na 25, 50, 75, i 95% radne duljine instrumentacije, a za svaku poziciju igle postavljeni su ulazni volumni protoci irigatora od 0,05; 0,1; 0,2; 0,3 i 0,4 ml s-1. Ukupno 60 simulacija endodontske irigacije izvršeno je pomoću CFD komercijalnog računalnog programa. Rezultati: Vrijednosti brzine i uzorci protoka irigatora pokazuju manju učinkovitost irigacije kod primjene igle zatvorenog vrha s otvorom sa strane, u odnosu na igle otvorenog vrha, narezanu i zakošenu, pri istoj dubini aplikacije irigacijske igle. Porast volumnog protoka praćen je porastom tlaka irigatora, za sve vrste i dubine aplikacije irigacijskih igala korištene u ovom istraživanju. Zaključak: Oblik humanog korijenskog kanala dobiven uporabom kompjutorizirane tomografije moguće je primijeniti u analizi endodontske irigacije metodom računalne dinamike fluida. Vrsta i dubina aplikacije irigacijske igle, kao i ulazni volumni protok Virigatora, utječu na sve analizirane vrijednosti; brzinu i tlak, te uzorak protoka irigatora. |
Sažetak (engleski) | Objectives: The influence of the needdle type, insertion depth and irrigant flow rate on irrigant flow pattern, flow velocity and apical pressure during endodontic irrigation was analyzed by ex-vivo based computational fluid dynamics (CFD) method. Material and Methods: Human upper canine root canal was prepared using rotary files, contrast fluid was introduced and the root canal was scanned by computed tomography (CT) providing three-dimensional object that was exported to computer-assisted design (CAD) software. Two probe points were established in apical portion of root canal model for flow velocity and pressure measurment. Three different irrigation 27G needle CAD models (closed-end side-vented, notched open-end and bevel open-end) were created and placed at 25, 50, 75 and 95% of the working length. Flow rates of 0.05, 0.1, 0.2, 0.3 and 0.4 ml s-1 were aplied. Total of 60 irrigation simulations were performed by computational fluid dynamics (CFD) fluid flow solvent software. Results: Closed-end side-vented needle requires insertion depth closer to instrumentation working lenght, regarding irrigant replacement efficiency, comparing to open-end irrigation needle types that show increased irrigant apical pressure and velocity. The increase of flow rate was followed by increased irrigant apical pressure for all irrigation needle types and needle insertion depths analyzed in this study. Conclusions: The human root canal shape obtained by CT is applicable in the creation of the CFD analysis of endodontic irrigation. All the analyzed values; irrigant VIIflow pattern, velocity and pressure, are influenced by application of different irrigation needle types, as well as needle insertion depth and irrigant flow rate. |