Naslov PROJEKT SUSTAVA GRIJANJA, HLAĐENJA I KLIMATIZACIJE PROIZVODNO POSLOVNE ZGRADE U GOSPODARSKOJ ZONI VARAŽDIN
Naslov (engleski) DESIGN OF HEATING COOLING AND AIR CONDITIONING SYSTEM OF MANUFACTURING HALL AND BUSINESS BUILDING IN THE ECONOMIC ZONE VARAŽDIN
Autor Draženko Gavranić
Mentor Tihomir Mihalić (mentor)
Član povjerenstva Nenad Mustapić (predsjednik povjerenstva)
Član povjerenstva Radoslav Korbar (član povjerenstva)
Član povjerenstva Tihomir Mihalić (član povjerenstva)
Član povjerenstva Natalija Kusanić Belinić (član povjerenstva)
Ustanova koja je dodijelila akademski / stručni stupanj Veleučilište u Karlovcu (Strojarski odjel) (Specijalistički diplomski stručni Studij strojarstva - izvanredni studij) Karlovac
Datum i država obrane 2020-11-10, Hrvatska
Znanstveno / umjetničko područje, polje i grana TEHNIČKE ZNANOSTI Strojarstvo Opće strojarstvo (konstrukcije)
Sažetak Geotermalna dizalica topline voda - voda koristi se kao uređaj koji koristi akumuliranu toplinu podzemne vode i uz pomoć električne energije pretvara toplinsku energiju ovisno o potrebi projektiranog arhitektonskog objekta u energiju potrebnu za sustav grijanja ili hlađenja. Za potrebe zahvaćanja podzemne vode koristi se sustav bunarske vode koji se sastoji od dva crpna bunara koji međusobno trebaju biti razmaknuti najmanje deset metara i jednog ponornog bunara. U ovom radu napravljeni su proračuni i toplinska bilanca za dizalicu topline voda – voda za proizvodno poslovnu zgradu. Proizvodno poslovna zgrada korisne površine 3029 m2 za koju je potrebno projektirati sustav grijanja, ventilacije i klimatizacije (GViK) nalazi se u gospodarskoj zoni grada Varaždina. Prema normi HRN EN 12831 proračunati su toplinski gubici koji iznose 197,4 kW u temperaturnom režimu grijanja 55/45 °C, a prema normi VDI 2078 proračunati su toplinski dobici koji iznose 291,2 kW u temperaturnom režimu 7/12 °C. Pasivno hlađenje projektirano je za potrebe proizvodne hale u iznosu toplinskih dobitaka 58,5 kW i prolaskom hladne vode u režimu 16/19 ºC. Za ventilaciju proizvodnog pogona i skladišta projektirane su klima komore kapaciteta 20000 m3/h za proizvodni pogon odnosno 6000 m3/h za skladište s pripadajućim kanalima za odvod i dobavu zraka. Za zasebne cjeline uredskog dijela zgrade proračunati su i projektirani ventilacijski uređaji s rekuperatorom zraka i kanalnim sustavom. Ventilacija sanitarnih čvorova izvedena je malim tihim ventilatorima s odgodom početka rada. Za cjelogodišnje hlađenje tehničkih soba, projektom je predviđeno hlađenje mono split klima uređajima kapacitete 3,6 kW za GRO sobu i 5 kW za server sobu. Temeljni zadatak i cilj svakog sustava grijanja, ventilacije i klimatizacije je osiguravanje toplinskih uvjeta (toplinske ugodnosti) kod kojih se korisnici prostora osjećaju ugodno. Za postizanje navedenog zadatka temeljem idejnog rješenja sustava grijanja, ventilacije i klimatizacije prema zadanom prostoru potrebno je napraviti kvalitetnu građevinsku izvedbu prostor s naglaskom na izolaciji prostora, precizne proračune toplinske bilance i temeljem proračuna napraviti pravilan odabir opreme.
Sažetak (engleski) Geothermal water-to-water heat pump is used as a device that uses the accumulated heat of groundwater and with the help of electricity converts thermal energy depending on the needs of the designed architectural object into energy needed for the heating or cooling system. For the purpose of groundwater abstraction, a well water system is used, which consists of two pumping wells that should be at least ten meters apart and one abyssal well. In this paper, calculations and heat balance for water - water heat pump for production and business building are made. The production and business building with a usable area of 3029 m2 for which it is necessary to design the GViK system is located in the economic zone of the city of Varaždin. According to the standard HRN EN 12831, heat losses amounting to 197.4 kW in the heating temperature regime of 55/45 °C were calculated, and according to the VDI 2078 standard, heat gains amounting to 291.2 kW in the temperature regime 7/12 °C were calculated. Passive cooling is designed for the needs of the production hall in the amount of heat gains of 58.5 kW and the passage of cold water in the mode of 16/19 ºC. For ventilation of the production plant and storage, air-conditioning chambers with a capacity of 20000 m3/h for the production plant and 6000 m3/h for the storage with associated ducts for air outlet and supply have been designed. For separate units of the office part of the building, designed ventilation devices with an air recuperator and a duct system were calculated. Ventilation of sanitary facilities is performed by small silent fans with a delay in the start of work. For year-round cooling of technical rooms, the project envisages cooling with mono-split air conditioners with a capacity of 3.6 kW for the GRO room and 5 kW for the server room. The basic task and goal of any heating, ventilation and air conditioning system is to provide thermal conditions (thermal comfort) in which the users of the space feel comfortable. In order to achieve this task, based on the conceptual design of the heating, ventilation and air conditioning system according to the given space, it is necessary to make a quality construction with emphasis on space insulation, precise heat balance calculations and make the right choice of equipment.
Ključne riječi
grijanje
hlađenje
ventilacija
dizalica topline
Ključne riječi (engleski)
heating
cooling
ventilation
heat pump
Jezik hrvatski
URN:NBN urn:nbn:hr:128:792747
Studijski program Naziv: Strojarstvo Vrsta studija: stručni Stupanj studija: preddiplomski Akademski / stručni naziv: stručni/a prvostupnik/ prvostupnica (baccalaureus/baccalaurea) inženjer/inženjerka strojarstva (bacc. ing. mech.)
Vrsta resursa Tekst
Način izrade datoteke Izvorno digitalna
Prava pristupa Otvoreni pristup
Uvjeti korištenja
Datum i vrijeme pohrane 2021-03-19 14:18:54